Nitric Oxide Sensor (NO) | 0 - 200 ppm |

Save 23%

Price:
Sale price$275.00 Regular price$355.00

Model: FD-NO-SENSOR
Datasheet: Click Here PDF
Availability: Usually in stock
Compatible: FD-90A-NO

Features

  • ⚛️ High precision and long life (2 years)
  • 🚄 Fast response speed, fast return to zero (T< 30 seconds) 
  • 🔋 Low power consumption, high sensitivity
  • 🔬Wide linear range, strong anti-interference ability
  • 💪 Excellent repeatability and stability

Description

These are generic NO sensors used as the pin-to-pin replacement of the standard 4-series electrochemical sensors. It is used throughout many gas detector brands and is an excellent NO gas sensor replacement element.

Our NO sensor employs an advanced electrolytic mechanism where nitric oxide and oxygen interact through precise redox reactions on specialized electrodes. By generating an electrical current directly proportional to the gas concentration, this sophisticated sensor enables accurate measurement of nitric oxide levels. The current's magnitude provides a quantitative assessment of NO presence in various industrial and environmental monitoring applications.

Nitric oxide detection technologies play a critical role across diverse industrial and environmental domains. From manufacturing facilities and urban infrastructure to environmental protection, NO detectors provide comprehensive gas concentration insights. These advanced sensing systems enable precise measurement, early warning mechanisms, and critical monitoring, supporting public health, environmental safety, and technological innovation in multiple application sectors.

Instructions

  • Once replaced and installed in your gas detector or analyzer, please let it sit for 24 hours so the sensor can stabilize to your environment. This step is very important.
  • Then undertake the appropriate zero and calibration for your specific gas detector. See your gas detector manufacturer's specific instructions.
  • Once calibrated, your gas analyzer will be ready for use.

Specifications

Detection Principle Electrochemical 3 electrodes
Detection Gas NO
Detection Range 0-250 PPM
Maximum Load Concentration 1000 PPM
Output Signal 400±200 nA/PPM
Zero Drift -2~10 PPM
Resolution 1 PPM
Response Time ≤30s
Bias Voltage +300 mV
Load Resistance 5~30Ω
Working Temperature -30℃-50℃
Working Humidity 15%RH to 90%RH (no condensation)
Repeatability <±2% output signal
Long-term Stability <2% signal/month
Linearity 1000 PPM
Work Pressure 90 to 110 kPa
Shelf Life 12 months after delivery
Service Life 2 years

Cross-Sensitivity Data

Interference Gas Gas Concentration Used (ppm) Value Displayed (ppm NO)
CO 100 0
SO2 23 2
H2S 26 35
CL2 18 1.5
NO2 20 10
HF 10 1